Electrical Data
Input Voltage: 90-264 VAC
Charge Voltage:
- Timer: 14.7 V ± 0.2
- Float: 13.8 V ± 0.3
Max. output power: 60W
Load Regulation: < 200 mV
Line regulation: < 100 mV
Switch frequency, approx.: 40 kHz
Leakage current with mains disconnected: < 100 uA
Temperature range: -10°C to +40°C / 14°F to 104°F
Ripple: < 100 mV p-p
Efficiency (at 100% load): > 81 %
Current limit: 4 A ± 0.3
Protection: Auto. resettable fuse protects the charger against wrong polarity.
Insulation class: II
Electrical safety: EN 60601-1,EN 60950, EN 60335-2-29
EMC standards
- Medical: EN 60601-1-2
- Emission: EN 61000-6-3
- Immunity: EN 61000-6-1
Indicator:
- Orange (constant current, boost): 4 A
- Yellow (constant voltage, timer): 14.7 V
- Green (constant voltage, float): 13.8 V
Timer: 2h ± 30 min
Output terminals: Battery clips, push-on terminals, DC connector
IP-code: 67
Dimensions [Metric]: 140 x 48 x 83 mm
Dimensions [Imperial]: 5.5 x 1.9 x 3.2 in
Weight: 1045 g / 37 oz
Recommended batt. capacity: 15 - 90 Ah